• Particle Size Analyzer with Dynamic Light Technology
  • Particle Size Analyzer with Dynamic Light Technology
  • Particle Size Analyzer with Dynamic Light Technology
  • Particle Size Analyzer with Dynamic Light Technology
  • Particle Size Analyzer with Dynamic Light Technology
  • Particle Size Analyzer with Dynamic Light Technology

Particle Size Analyzer with Dynamic Light Technology

After-sales Service: 1 Year
Warranty: 1 Year
Max Diameter of Workpiece: <500mm
Samples:
US$ 10000/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Particle Size Analyzer with Dynamic Light Technology pictures & photos
Particle Size Analyzer with Dynamic Light Technology
US $8,700-10,000 / Piece
Min. Order: 1 Piece

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Specification
  • Detailed Photos
  • Customer praise
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
SKZ1062A
Mass Scope of Workpiece
<900kg
Type
Material Testing Machine
Maxcapacity
<1000KN
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Product Name
Particle Size Analysis Laser Diffraction Particle
Principle
Mie Scattering Theory
Standard
ISO 13320-1
Measure Range
0.1um--800um
Detector Channels
70
Laser Parameter
Imported Semiconductor Fiber Laser, R= 635nm, P>10
Operating Mode
Software Fully Automatic Operation
Test Speed
<1min/Time
Optical Path Calibration
Optical Path Auto-Calibration
Accuracy
<1%
Transport Package
Wooden Box
Specification
840mm*370mm*430mm 30kg
Trademark
SKZ
Origin
China
HS Code
9027809990
Production Capacity
500

Packaging & Delivery

Package Size
98.00cm * 51.00cm * 56.00cm
Package Gross Weight
53.000kg
Lead Time
14 days (1 - 1 Pieces)
To be negotiated ( > 1 Pieces)

Product Description

 
Product Description
Particle Size Analyzer with Dynamic Light Technology

SKZ1062A Cypermetrine Chlorphiriphos PSA Analyzer

Introducing the SKZ1062A Cypermetrine Chlorphiriphos PSA Analyzer, the perfect solution for accurate particle size analysis. With its advanced technology and user-friendly design, this analyzer is a must-have for any laboratory or research facility.

Technical Specifications

  • Measuring Range: 0.1~800 μm (SKZ1062A), 0.02~1200 μm (SKZ1062A-1)
  • Accuracy Tolerance: ± 1% (national standard D50)
  • Deviation of Repeatability: ± 1% (national standard D50)
  • Electrical Requirements: AC 220 ± 10V, 50Hz, 200W

Principle

The SKZ1062A Cypermetrine Chlorphiriphos PSA Analyzer utilizes Mie scattering theory to accurately measure particle size distribution. By considering the refractive index of the particles and the dispersion medium, this analyzer provides reliable data for particle sizing calculations. With its unconstrained fitting inversion method, it ensures precise and unbiased results.

Features

  • Advanced Light Path Design: The concentrated light Fourier transform test technology improves resolution and ensures maximum range.
  • Fully Sealed Fiber-Optic Semiconductor Laser: The high-stability, long-life laser guarantees superior test repeatability.
  • Laser Power Monitoring and Automatic Adjustment: Constant power laser with real-time detection and automatic adjustment function for consistent performance.
  • Fully Automatic Test: Simply put the sample and let the analyzer do the rest. No manual data selection required.
  • Ultrasonic Anti-Dry Function: Protects the ultrasound from damage in the absence of water.
  • Dustproof and Shockproof Design: Sealed instrument and anti-vibration structure ensure durability and reliable test results.

With the SKZ1062A Cypermetrine Chlorphiriphos PSA Analyzer, you can achieve accurate and efficient particle size analysis. Trust in its advanced technology and user-friendly features to enhance your research and analysis processes. Order yours today from SKZ International Co., Ltd., a trusted name in particle size analysis equipment.

Specification
Standard ISO 13320-1:1999,GB/T19077.1-2008
Test Range 0.1um--800um
Detector channels 70
Accuracy <1%
Repeatability error <0.5%
Free bubble With bubble-free design, no bubble interference, the data is more accurate.
Mis-operation protection It has a mis-operation protection function and does not respond to mis-operations.
Laser parameter Imported semiconductor fiber laser, λ= 635nm, p>10mW
Optical path calibration Optical path auto-calibration
Dispersion method Ultrasound Frequency: f=40KHZ, power: p=100W, time: adjustable. With ultrasonic anti-dry
  Circulation, mixing Cycle mixing integrated design, speed: 100-3950rpm adjustable speed.
  Circulating flow Rated flow: 0-10L/min adjustable, rated power: 25W.
  Sample cell Self-designed boiling sample cell, better dispersion, capacity: 190-600ml.
Dustproof, shockproof Dustproof and shockproof design
Software Analysis mode Including free distribution, R-R distribution and lognormal distribution, according to the hierarchical statistical model, to meet the different requirements of different industries for the statistical method of sample size measurement
  Statistical methods Volume distribution and number distribution, to meet the different sectors for statistically different particle size distributions
  Statistical comparison It can be used for statistical comparison analysis of multiple test results, which can obviously compare the difference of test results under different time and different conditions, and has strong practical significance for the control of injection conditions and injector quality.
  Self-DIY The user customizes the data to be displayed, based on the particle size, the particle size according to the percentage or the percentage according to the particle size interval, to meet the characterization of the particle size test in different industries. Span, consistency, interval accumulation
  Testing report The test report can export various forms of documents such as Word, Excel, Picture (Bmp) and Text (Text), which can be used to view test reports and research results in scientific research articles in any situation.
  Multi-language Chinese and English language interface support, and other language interfaces can be embedded according to user requirements.
  Intelligent operation mode Really fully automatic operation, no one interferes with the factors, you only need to spray the sample to be tested according to the prompt, the test results are more repeatable.
Operating mode Software fully automatic operation
Test speed <1min/time
Size 840mm*370mm*430mm
Weight 30Kg
Detailed Photos
Particle Size Analyzer with Dynamic Light Technology
Customer praise
Particle Size Analyzer with Dynamic Light Technology
Company Profile
Particle Size Analyzer with Dynamic Light TechnologyParticle Size Analyzer with Dynamic Light TechnologyParticle Size Analyzer with Dynamic Light TechnologyParticle Size Analyzer with Dynamic Light Technology
FAQ
Particle Size Analyzer with Dynamic Light Technology

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Particle Size Analyzer with Dynamic Light Technology pictures & photos
Particle Size Analyzer with Dynamic Light Technology
US $8,700-10,000 / Piece
Min. Order: 1 Piece

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory, Trading Company
Registered Capital
3000000 RMB
Plant Area
101~500 square meters