Skz1064b 0.0001c Adiabatic Bomb Calorimeter Advanced Oxygen Bomb Calorimetery

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Still deciding? Get samples of US$ 12300/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 15 foreign trading staff(s) and 7 staff(s) with over 6 years of overseas trading experience
R&D Capabilities
The supplier has 2 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (18)
  • Skz1064b 0.0001c Adiabatic Bomb Calorimeter Advanced Oxygen Bomb Calorimetery
  • Skz1064b 0.0001c Adiabatic Bomb Calorimeter Advanced Oxygen Bomb Calorimetery
  • Skz1064b 0.0001c Adiabatic Bomb Calorimeter Advanced Oxygen Bomb Calorimetery
  • Skz1064b 0.0001c Adiabatic Bomb Calorimeter Advanced Oxygen Bomb Calorimetery
  • Skz1064b 0.0001c Adiabatic Bomb Calorimeter Advanced Oxygen Bomb Calorimetery
  • Skz1064b 0.0001c Adiabatic Bomb Calorimeter Advanced Oxygen Bomb Calorimetery
Find Similar Products
  • Overview
  • Product Description
  • Customer praise
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
SKZ1064B
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Heat Capacity
5mj/Kg-40mj/Kg
Measuring Range
5c-40c
Resolution
0.0001c
Measurement Accuracy
60j/G
Relative Standard Deviation
0.1%
Test Interval
13min
Pressure Endurance of Bomb
20 MPa
Temperature Measurement Range
10c-28c
Relative Humidity
85%
Power
AC 220V&+-5%, 50 Hz
Dimension
540mm*420mm*420mm
Transport Package
Wooden Box Package
Specification
60*48*46 cm 55kg
Trademark
SKZ
Origin
China
HS Code
9027809990
Production Capacity
500

Packaging & Delivery

Package Size
60.00cm * 48.00cm * 46.00cm
Package Gross Weight
55.000kg
Lead Time
14 days (1 - 1 Pieces)
To be negotiated ( > 1 Pieces)

Product Description

Product Description

Skz1064b 0.0001c Adiabatic Bomb Calorimeter Advanced Oxygen Bomb CalorimeterySKZ1064B Oxygen Bomb Calorimeter

Oxygen bomb calorimeter can be used to measure the calorific value of solid or liquid samples, measuring samples in a closed container (oxygen bomb), oxygen-filled environment, the heat generated by combustion, the measurement results called the combustion value, calorific value , BTU and so on.

Calorific value results have the value of determining other values to determine the quality of the sample as a basis for calculating the price (eg, coal), as well as physiology (eg, energy distribution in ecology, energy metabolism in animal nutrition studies, etc.), physical And the chemical conclusion.

Features
1. A semiconductor cooling, cooling capacity may be determined according to high and low calorific value
2. Automatically adjust the water temperature to keep the water temperature relatively constant and achieve continuous long-term tests to ensure accurate results.
3. Using a USB interface, a computer can control multiple calorimeters.
4. Carrying electronic measuring cup, no manual weighing water, the inner cylinder automatically measuring the amount of water, repeated error <0.4g.
5. The ignition wire resistance can be measured automatically, and the ignition wire is automatically checked before the test.
6. Standardized piping design, greatly shorten the pipeline, the pipeline is more reasonable, more accurate results
7. Using a special interface to discharge water, drainage equipment, changing the water more easily and quickly.
 

Technical specifications
Heat capacity 5MJ/kg~40MJ/kg
Measuring range (5~40)ºC
Resolution 0.0001ºC
Measurement accuracy ± 60J/g
Relative standard deviation ≤0.1%
Test interval ≤13min
Pressure endurance of bomb 20 MPa
Temperature measurement range 10 ºC~28 ºC
Relative humidity ≤85%
Power AC 220V±5%, 50 Hz
Dimension 540mm×420mm×420mm mm
Weight 55kg

 

Customer praise

Skz1064b 0.0001c Adiabatic Bomb Calorimeter Advanced Oxygen Bomb Calorimetery

Packaging & Shipping

Skz1064b 0.0001c Adiabatic Bomb Calorimeter Advanced Oxygen Bomb Calorimetery

Company Profile

Skz1064b 0.0001c Adiabatic Bomb Calorimeter Advanced Oxygen Bomb CalorimeterySkz1064b 0.0001c Adiabatic Bomb Calorimeter Advanced Oxygen Bomb CalorimeterySkz1064b 0.0001c Adiabatic Bomb Calorimeter Advanced Oxygen Bomb CalorimeterySkz1064b 0.0001c Adiabatic Bomb Calorimeter Advanced Oxygen Bomb Calorimetery

FAQ

Skz1064b 0.0001c Adiabatic Bomb Calorimeter Advanced Oxygen Bomb Calorimetery

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier