• Skz1061A 80c ASTM C 518 ISO8302 Guarded Hot Plate Thermal Conductivity Coefficient Thermal Analyzer Thermal Conductivity Meter
  • Skz1061A 80c ASTM C 518 ISO8302 Guarded Hot Plate Thermal Conductivity Coefficient Thermal Analyzer Thermal Conductivity Meter
  • Skz1061A 80c ASTM C 518 ISO8302 Guarded Hot Plate Thermal Conductivity Coefficient Thermal Analyzer Thermal Conductivity Meter
  • Skz1061A 80c ASTM C 518 ISO8302 Guarded Hot Plate Thermal Conductivity Coefficient Thermal Analyzer Thermal Conductivity Meter
  • Skz1061A 80c ASTM C 518 ISO8302 Guarded Hot Plate Thermal Conductivity Coefficient Thermal Analyzer Thermal Conductivity Meter
  • Skz1061A 80c ASTM C 518 ISO8302 Guarded Hot Plate Thermal Conductivity Coefficient Thermal Analyzer Thermal Conductivity Meter

Skz1061A 80c ASTM C 518 ISO8302 Guarded Hot Plate Thermal Conductivity Coefficient Thermal Analyzer Thermal Conductivity Meter

Warranty: 1 Year
Product Name: Skz1061A Guarded Hot Plate Thermal Conductivity Te
Thermal Conductivity Coefficient Range: 0.010 ~ 5.000 W (K.M)
Maximum Hot Plate Set Temperature: 80c
Standard: ISO8302, ASTM C 518
Sample Size: 300 * 300 * 30mm
Samples:
US$ 6500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
SKZ1061A
Accuracy of Temperature Control
0.05c
Temperature Resolution
0.01c
Trademark
SKZ
HS Code
9027809990
Production Capacity
500

Product Description

Skz1061A 80c ASTM C 518 ISO8302 Guarded Hot Plate Thermal Conductivity Coefficient Thermal Analyzer Thermal Conductivity Meter Application
Single material:
foam (insulation material surface flat, plate), polyurethanes, phenolic, urea-formaldehyde, mineral wool (glass wool, rock wool, mineral wool), cement wall.

Composite materials:
glass composite CRC, cement enhanced polyphony board, sandwich concrete, fiber glass panel composite plate, paper cellular plate

Standards:
ISO8302: Thermal insulation. Determination of steady-state thermal resistance and related proper 

 Feature:
1. The surface temperature is uniformity and accurate. 
Using large block purple COINS as Temperature profile board in the design to improve the consistency of the surface temperature of the test sample.
2. Advanced control system to control the temperature quickly and steadily.
3. Friendly human-machine interface.
Both cold and hot plate temperature and heat flux power can be intuitively displayed by large screen LCD.
4. Simple operation.
Electric moveable holder and clamping force can be adjusted on the LCD, Insulation door can be shut down automatically after sample installation.
5. Intelligent data processing.
Highly automated computer data communication and report processing system, Flat thermal conductivity meter has computer communication interface, which can display temperature curve in real time.
6. Automatically generate test report and print.
Built-in test records, data processing and report format, can issue test report automatically.

Technical parameters:
Biggest test pieces size Length * width * thick: 300 * 300 * 30mm
Sample size 300mm * 300mm * δ (5-30) mm
Accuracy of temperature control 0.05 ºC
Resolution 0.01 ºC
Maximum hot plate set temperature 80 ºC
Minimum cooling-plate set temperature room temperature in a standard lab
recommended 20 ºC, limits to 10 ºC
Accuracy of measurement 3%
Thermal conductivity Coefficient range 0.010 ~ 5.000 w (k.m)
Power AC 220V
Testing time 40-60minutes

Skz1061A 80c ASTM C 518 ISO8302 Guarded Hot Plate Thermal Conductivity Coefficient Thermal Analyzer Thermal Conductivity MeterSkz1061A 80c ASTM C 518 ISO8302 Guarded Hot Plate Thermal Conductivity Coefficient Thermal Analyzer Thermal Conductivity MeterSkz1061A 80c ASTM C 518 ISO8302 Guarded Hot Plate Thermal Conductivity Coefficient Thermal Analyzer Thermal Conductivity MeterSkz1061A 80c ASTM C 518 ISO8302 Guarded Hot Plate Thermal Conductivity Coefficient Thermal Analyzer Thermal Conductivity MeterSkz1061A 80c ASTM C 518 ISO8302 Guarded Hot Plate Thermal Conductivity Coefficient Thermal Analyzer Thermal Conductivity MeterSkz1061A 80c ASTM C 518 ISO8302 Guarded Hot Plate Thermal Conductivity Coefficient Thermal Analyzer Thermal Conductivity MeterSkz1061A 80c ASTM C 518 ISO8302 Guarded Hot Plate Thermal Conductivity Coefficient Thermal Analyzer Thermal Conductivity Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
Registered Capital
3000000 RMB
Plant Area
101~500 square meters