Product Highlights

  • ISO 22007-2 Standard Compliance: Meets ISO 22007-2 2008 standard for accurate thermal conductivity testing.
  • Fast Transient Measurement: Tests completed in 5 to 160 seconds using Transient Plane Source Technology.
  • Wide Material Compatibility: Tests solids, liquids, powders, pastes, gels, and various composite materials.
  • Non-Destructive Testing: Samples remain intact and can be reused after testing without damage.
  • Advanced ARM Processor: Host system uses ARM microprocessor for faster data processing and control.
  • User-Friendly Interface: Features color LCD display and touch screen controls for easy operation.
  • No Sample Preparation Required: Works with bulk solids and simple shapes without complex preparation.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter

Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter pictures & photos
Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter pictures & photos
Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter pictures & photos
Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter pictures & photos
Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter pictures & photos
Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter pictures & photos
Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
  • Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
  • Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
    Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
  • Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
    Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
  • Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
    Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
  • Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
    Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
  • Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
    Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
  • Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
    Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter

Find Similar Products

Product Description

SKZ1061C High precision ISO 22007-2 thermal conductivity and resistivity meter

It can be used for various heat conduction properties of different types of materials testing. Transient Plane Source method is to study the thermal conductivity method, the latest one, which makes measurement technology to a whole new level. In the study of material capable of fast and accurate measurement of thermal conductivity for the enterprise quality control, material production and laboratory studies provide a great convenience. The instrument is easy to operate, simple to understand, will not cause damage to the sample.
Test object:

Metal, ceramics, alloys, minerals, polymers, composite materials, paper, fabric, foam (smooth surface insulation material, plate), mineral wool, cement walls, glass-reinforced composite plate CRC, cement polystyrene board, sandwich concrete, glass and steel panels composite plates, paper honeycomb panels, gel, liquid, powder, granular and pasty solid.
 
Features:
1. Standard: ISO 22007-2 2008.
2. Direct measurement, testing time is about 5-160s, and can be set up, to quickly and accurately measure the coefficient of thermal conductivity, saving a lot of time.
3. Do not suffer the effects of thermal contact resistance.
4. No need special sample preparation, sample shapes without special requirements, bulk solids, only need the relatively smooth surface and satisfies the length and width of at least twice the diameter of probe can be.
5. Non-destructive testing on samples, samples can be reused.
6. The probe using the double-helix structure design, combined with the exclusive model, data collected on the probe using the core algorithm analysis.
7. Sample stage designed, easy operation, suitable for different thickness of the sample
8. The probe data acquisition using the imported data acquisition on the chip, which is high resolution, can make the tests more accurate and reliable results.
9. Host control system using the ARM microprocessor, speed is faster than traditional microprocessors, improves the processing capacity, more accurate results,
10. It can be used for measuring bulk solids,pasty solid, granular solid, paste, gel, liquid, powders, coatings, thin film thermal insulation materials.
11. Intelligent freiendly human-computer interface, color LCD display, touch screen controls
12. Powerful data processing capabilities. Highly automated computer processing system for data communication and reporting.
Specification
Technical parameters:
item
value
Warranty
12 months
Customized support
OEM
Place of Origin
China
 
Shandong
Brand Name
SKZ
Model Number
SKZ1061C
Power
Electronic
Product name
guarded hot plate thermal conductivity testing equipment
Standard
 ISO 22007-2 2008.
Sample Size
300 * 300 * 30mm
Temperature range
Room temperature--130ºC
Accruacy
±3%
Repeatability
≤3%
Thermal conductivity Coefficient range
0.005--300W/(m*K)
Testing time
5--160 seconds
Test method
Transient Plane Heat Source, Unsteady Status
Display
LCD color screen display
Detailed Photos

 

 

 

Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity MeterSkz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
Application scenarios
Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
OEM
Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
Our Advantages
Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity MeterSkz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity MeterSkz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity MeterSkz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
Company Profile
Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
Packaging & Shipping
Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter
After Sales Service
Skz1061c High Precision ISO 22007-2 Thermal Conductivity and Resistivity Meter

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR245904". Items marked "verified" are certified.

Watch Video
Watch Video
SKZ International Co., Ltd.
SKZ International Co., Ltd.
SKZ International Co., Ltd.
SKZ International Co., Ltd.
SKZ International Co., Ltd.
SKZ International Co., Ltd.
SKZ International Co., Ltd.
SKZ International Co., Ltd.

About Our Factory & Business Background

Address
212, Quanjingyayuan Bld, Wolong Road, Jinan, Shandong, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DDP, DAP, CIP, CPT
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Beijing, Qingdao, Shanghai,Shenzhen

Our Production Capability & Technical Expertise

Main Products
Thermal Analysis, Water Quality Analyzer, Textile Testing, Pulp Testing, Rubber and Plastictesting, Density Meter, Electronic Balance, Gas Detector, Moisture Meter, Paper and Paperboard Testing

Our Industry Experience & Global Business Record

Export Year
2016-03-07
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the warranty period for this meter?
The product comes with a 1-year warranty covering mechanical defects.
What materials can be tested with this device?
It supports testing of metals, ceramics, alloys, polymers, liquids, powders, pastes, gels, and various composite materials.
How long does a single test take?
Testing time ranges from 5 to 160 seconds depending on the material and settings.
Is the testing process destructive to the sample?
No, the device performs non-destructive testing, allowing samples to be reused.
Does the device support OEM or ODM customization?
Yes, OEM, ODM, and OBM customized support are available.
What is the lead time for orders?
The average lead time is within 15 working days for both peak and off-peak seasons.

Send your message to this supplier