Product Description
ISO13320 wet dispersion distribution analysis Mie scattering 0.1-800um Wet method Mie scattering particle size analyzer price
Technical parameter:
Standard: ISO13320
1. Measuring range: 0.1~800 μm(SKZ1062A), 0.02~1200 μm(SKZ1062A-1)
2. Accuracy tolerance: ± 1% (national standard D50)
3. Deviation of repeatability: ± 1% (national standard D50)
4. Electrical requirements: AC 220 ± 10V,50Hz, 200W
Principle:
Mie scattering theory with full-scale, fully taking into account the refractive index of the optical properties of the particles
and the dispersion medium measured particle size distribution data, depending on the size of the particles in each angle scattered light intensity changes on the anti-particle group performances. Particle sizing calculations are generally divided into unconstrained fitting inversion and the constrained fitting inversion. Constrained fitting inversion before the calculation assumes that match a certain distribution of particle group, according to the law of inverse particle size distribution. This type of operation is relatively simple, but because of prior assumptions inevitably exists between the reality of bias, thereby testing the constrained fitting data do not reflect the actual particle size distribution of the particles.
Unconstrained fitting inversion test before the particle does not make any assumptions, by light intensity directly and accurately calculate the size distribution of particles. Such assumptions are reasonable detector and particle classification, to make high demands on the device itself. SKZ1062 Wet-laser particle size Analyzer, using optimum of non-uniform cross-dimensional fan-shaped array of detector arrays and reasonable size grading, making it possible to accurately measure particle size distribution.
Feature
★Advanced light path design: Adopting concentrated light Fourier transform test technology to ensure maximum range at the shortest focal length and effectively improve resolution; unique high-density detection unit can test small particles and high-density detection unit to make it super strong Full scale seamless testing capability.
★ Fully sealed fiber-optic semiconductor laser: It adopts a high-stability, long-life fully-sealed imported fiber-optic
semiconductor laser. Its excellent stability gives it superior test repeatability (lifetime is more than 30,000 hours).
★ Laser power monitoring and automatic adjustment: The exclusive use of constant power laser, real-time detection of laser power and automatic adjustment function, effectively avoiding the problem of laser power attenuation caused by long-term use. At the same time, the constant current and constant voltage high-filter laser power supply is used to effectively extend the life of the laser, and the normal use reaches more than 30,000 hours.
★ Fully automatic test: Really automatic test, all you have to do is put the sample, no interference data, no need to manually select the data.
★ Ultrasonic anti-dry function: Ultrasonic anti-dry function can be realized to avoid damage to ultrasound in the absence of water.
★ Dustproof and shockproof design: The whole instrument has been sealed and designed to greatly improve the service life of internal components. The unique anti-vibration structure can effectively avoid the interference of external vibration to the instrument, and make the test result more stable and reliable.
★Automatic alignment: The exclusive use of the combination of mechanical center and optical center, the optical path automatically adjusts the positioning more accurately, reaching the micron level; at the same time, the optical path adjustment speed is faster and faster and can be adjusted in 15 seconds. The self-developed automatic alignment system consists of stepper motor, precision guide rail, precision controller and software system. The minimum step distance is 0.2 microns, ensuring that the focus of the laser beam always passes through the center point of the detector, improving the accuracy of the test results and testing.Repeatability.
★ Free bubble design: The new design makes no bubbles enter the test sample window and avoids air bubble interference.
★ Sample no residue design: The instrument pipeline and drainage structure have been optimized, and there is no residual liquid in the instrument pipeline and circulation pump to avoid the impact on the next test data.
★ Sample window quick change device: The newly designed sample window quick change device makes the sample window replacement more convenient and quick.
Specification
Standard |
ISO 13320-1:1999,GB/T19077.1-2008 |
Test Range |
0.1um--800um |
Detector channels |
70 |
Accuracy |
<1% |
Repeatability error |
<0.5% |
Free bubble |
With bubble-free design, no bubble interference, the data is more accurate. |
Mis-operation protection |
It has a mis-operation protection function and does not respond to mis-operations. |
Laser parameter |
Imported semiconductor fiber laser, λ= 635nm, p>10mW |
Optical path calibration |
Optical path auto-calibration |
Dispersion method |
Ultrasound |
Frequency: f=40KHZ, power: p=100W, time: adjustable. With ultrasonic anti-dry |
|
Circulation, mixing |
Cycle mixing integrated design, speed: 100-3950rpm adjustable speed. |
|
Circulating flow |
Rated flow: 0-10L/min adjustable, rated power: 25W. |
|
Sample cell |
Self-designed boiling sample cell, better dispersion, capacity: 190-600ml. |
Dustproof, shockproof |
Dustproof and shockproof design |
Software |
Analysis mode |
Including free distribution, R-R distribution and lognormal distribution, according to the hierarchical statistical model, to meet the different requirements of different industries for the statistical method of sample size measurement |
|
Statistical methods |
Volume distribution and number distribution, to meet the different sectors for statistically different particle size distributions |
|
Statistical comparison |
It can be used for statistical comparison analysis of multiple test results, which can obviously compare the difference of test results under different time and different conditions, and has strong practical significance for the control of injection conditions and injector quality. |
|
Self-DIY |
The user customizes the data to be displayed, based on the particle size, the particle size according to the percentage or the percentage according to the particle size interval, to meet the characterization of the particle size test in different industries. Span, consistency, interval accumulation |
|
Testing report |
The test report can export various forms of documents such as Word, Excel, Picture (Bmp) and Text (Text), which can be used to view test reports and research results in scientific research articles in any situation. |
|
Multi-language |
Chinese and English language interface support, and other language interfaces can be embedded according to user requirements. |
|
Intelligent operation mode |
Really fully automatic operation, no one interferes with the factors, you only need to spray the sample to be tested according to the prompt, the test results are more repeatable. |
Operating mode |
Software fully automatic operation |
Test speed |
<1min/time |
Size |
840mm*370mm*430mm |
Weight |
30Kg |
Detailed Photos
Customer praise
Company Profile
FAQ